From The Manufacturerdo You Need An Efficient, Cost-Effective Way To Distribute, Monitor And Manage Power In An It Or Industrial Environment? Tripp Lite'S Pdumh20At Metered Power Distribution Unit With Ats Is The Solution You Seek! It Provides Sixteen Outlets Plus A Digital Meter That Displays Continuous Power Consumption, Enabling It Personnel To Monitor The Pdu'S Load On Site. Optional Integrated Automatic Transfer Switching Capability Enables Dual Ac Input Redundancy For Critical Network Hardware, Hot-Swappable Ups Maintenance Bypass Or Dual Ups Protection. The Pdumh20At Is Also Equipped With A Built-In Snmpwebcard Slot, Enabling It To Be Permanently Upgraded To A Switched Pdu. The Pdumh20At Features An All-Metal Housing And A Switchless Design To Prevent Accidental Shutoff. It Is Suitable For 1U Rackmount Installation As Well As Wall-Mount, Workbench, Under-Counter And Similar Installations. Key Features Pdumh20At Metered Power Distribution Unit Offers: Automatic Transfer Switching (Ats) To Provide A Redundant Power Option Digital Meter For On-Site Monitoring Of Total Pdu Load Upgradable To Switched Pdu With Optional Snmpwebcard Configurable For 1U Rackmount Installation 2-Year Warranty Reliable It Power Distributionclick Here For A Larger Image Digital Current Meter And Snmpwebcard Slotclick Here For A Larger Image Optimized For Demanding Applicationsthe Pdumh20At Is Designed For Reliable Distribution Of Ac Power To Supported Equipment In It, Industrial And Similar Applications. It Features A Rugged All-Metal Case, High-Quality Outlets, A 20A Circuit Breaker And A Switchless Design To Prevent Accidental Shutoff. Auto-Transfer Switching Function Adds Hot-Swap And Maintenance Bypass Ability To Standard Ups Configurations. Reliable It Power Distributionunfiltered Electrical Pass-Through Makes The Pdumh20At Ideal For Distributing Alternate Waveform Ups Or Generator Power In Rack Enclosures, Network Closets, And More. It Provides Sixteen 5-15/20R Outlets And Dual 12-Ft. Cords (One Attached, One Detachable) With Locking L5-20P Plugs To Prevent Accidental Disconnection. Two Included L5-20R To 5-20P Plug Adapters Enable The Pdu To Be Connected To Standard 5-15/20R Outlets. Integrated Auto-Transfer Switching & Hot-Swap Capabilitythe Pdumh20At Features Optional Integrated Automatic Transfer Switching (Ats) Capability To Provide A Redundant Power Option For Networking And Server Applications With Non-Redundant Internal Power Supplies. In Ats Mode, The Attached Power Cord Delivers Primary Input Power And The Included Detachable Power Cord Provides Secondary Input Power. If Primary Power Becomes Unstable Or Fails, The Pdu Automatically Switches To The Secondary Power Source. Additionally, Ats Enables Fault-Tolerant Hot-Swappable Ups Protection When Used With A Single Ups System, And Fully Redundant Ups Protection When Each Power Cord Is Connected To A Separate Ups System. Front-Panel Input Leds Indicate Primary Or Secondary Power Availability. Digital Current Meterassure Proper Load Balance With The Pdumh20At'S Easy To Read, Two-Character Digital Led Meter That Displays The Total Connected Equipment Load. This Meter Enables It Personnel To Monitor The Total Load On The Pdu In Real Time, Allowing More Equipment To Be Safely Connected With No Danger Of Overloading The Pdu Or Power Supply Circuits. Plus, The Outlets Are Factory Programmed For Sequential Turn-On When The Pdu Is First Powered On To Prevent Inrush-Related Equipment Interaction On Start-Up And Safeguard Against Costly Overloads. Optional Advanced Power Managementa Built-In Snmpwebcard Slot Enables The Pdumh20At To Be Permanently Upgraded To A Switched Pdu With Full Network Power Monitoring And Individual Outlet Control Capability. With An Snmpwebcard Installed, The Pdumh20At Can Also Be Custom Programmed For Power-On And Power-Off Sequences With User-Specified Time Delays In Response To Loss And Restoration Of Primary Input Power. Versatile Installation Optionsthe Pdumh20At Is Easy To Integrate With A Wide Range Of Data Center And Network Applications. It Is Suitable For 1U Installation In Standard 19-Inch Rack Enclosures As Well As Wall-Mount, Workbench, Under-Counter And Similar Installations. Two Included L5-20R To 5-20P Plug Adapters Enable The Pdu To Be Connected To Standard 5-15/20R Outlets. Switchless Designthe Pdumh20At'S Switchless Design Prevents Accidental Shutoff And Safeguards Against Downtime Due To Human Error. The L5-20P Plug Locks Into Place To Maintain A Secure Connection. Peace Of Mindthe Pdumh20At Comes With A 2-Year Warranty. Technical Specifications Tripp Lite Pdumh20At Metered Power Distribution Unit With Ats Click Here For A Larger Image Model: Pdumh20At Voltage Compatibility: 120 Vac Frequency Compatibility: 50/60 Hz Amps: 20 Outlet Quantity/Type: 16 X 5-15/20R Input Cord/Plug: 2 X 12 Ft./L5-20P (1 Attached, 1 Detachable) Led Display: 2-Character (Indicating Amps) Dimensions (Hwd): 1.75 X 17.5 X 14.5 In. (1U) Weight: 1
⚠️ WARNING (California Proposition 65): This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, please visit www.P65Warnings.ca.gov.
Frequently Asked Questions
Q: What are the dimensions of the Tripp Lite Metered PDU?A: The Tripp Lite Metered PDU measures fourteen point four nine inches in length, seventeen point four eight inches in width, and one point seven five inches in height.
Q: What is the power capacity of the Tripp Lite Metered PDU?A: The power capacity is twenty amps at one hundred twenty volts, making it suitable for various power distribution needs.
Q: How many outlets does the Tripp Lite Metered PDU have?A: It features sixteen NEMA five fifteen/twenty R outlets, providing ample connectivity for multiple devices.
Q: How do I install the Tripp Lite Metered PDU?A: You can install the PDU as a one U rackmount unit or mount it on a wall, workbench, or under a counter.
Q: Is the Tripp Lite Metered PDU easy to use?A: Yes, it is designed for easy installation and includes a digital meter for monitoring power consumption.
Q: Can I use the Tripp Lite Metered PDU for hot-swapping?A: Yes, it supports hot-swappable UPS maintenance bypass and provides dual UPS protection.
Q: How do I keep the Tripp Lite Metered PDU safe and in good condition?A: Ensure that it is installed in a well-ventilated area and avoid overloading the outlets to maintain safety.
Q: Does the Tripp Lite Metered PDU require any special maintenance?A: No special maintenance is required, but regular monitoring of power consumption is recommended.
Q: Is the Tripp Lite Metered PDU suitable for industrial applications?A: Yes, it is designed for reliable power distribution in IT and industrial environments.
Q: What if I receive a damaged Tripp Lite Metered PDU?A: Contact customer support immediately to report the damage and arrange for a return or replacement.
Q: Does the Tripp Lite Metered PDU come with a warranty?A: Yes, it includes a two-year limited warranty for peace of mind.
Q: Can I upgrade the Tripp Lite Metered PDU?A: Yes, it has a built-in SNMPWEBCARD slot for future upgrades to a switched PDU.
Q: What kind of cords does the Tripp Lite Metered PDU use?A: It comes with two twelve-foot NEMA L five twenty P plugs, one attached and one detachable.
Q: How fast does the Tripp Lite Metered PDU switch power sources?A: The unit can switch between power sources in just two to seven milliseconds.
Q: Is there a digital display on the Tripp Lite Metered PDU?A: Yes, it features a front-panel digital ammeter that displays power consumption in real-time.