Double-Conversion Ups Protects Equipment Against Damage, Downtime And Data Lossthis On-Line Double-Conversion Ups System Maintains Perfect Output By Converting Ac Input To Dc, Then Reconverting Ups Output To Fully Regulated Sine Wave Ac. Constant On-Line Operation Completely Isolates Sensitive Equipment From Every Power Problem On The Ac Line. The Smartonline Su1500Rtxlcdn Provides The Highest Level Of Power Protection And Battery Backup For Education, Healthcare, Military, Government And Other Mission-Critical It Applications Where Space Is Limited, But Premium Power Reliability Is Essential.Reliable, Expandable Battery Backup Keeps You Operational Through Power Outagesthe Field-Replaceable, Hot-Swappable Vrla Battery Modules Allow You To Work Through Short Power Failures And Give You Enough Time To Safely Save Files And Shut Down Your System In Case Of A Prolonged Blackout. Zero Transfer Time Between On-Line And Battery Modes Maintains Continuous Operation Of Connected Equipment Without Interruption Or Rebooting. Extra Runtime Is Available By Connecting Up To Four Optional Extended Battery Modules (Bp48Rt, Sold Separately).Pre-Installed Lx Platform Network Management Card Allows Remote Access 24/7The Webcardlxe Network Interface Enables Full Remote Configuration And Management, Including Load Shedding, Reboots Of Connected Equipment And Safe Shutdowns. The Ip-Based Auto Probe Feature Ensures Continuous Network Uptime By Communicating With Other Network Devices, Detecting Lost Connectivity And Automatically Rebooting It Equipment. Optional Envirosense2 Modules (E2Mt, E2Mtdo And E2Mthdi, All Sold Separately) Provide A Variety Of Environmental Monitoring And Control Options.Nema Outlets Protect Your Connected Componentseight 5-15R Outlets Provide Connected Equipment With Pure Sine Wave Ac Output And Allow You To Monitor Power Consumption Down To The Outlet Group Level. Power Provided By These Outlets Is Filtered To Protect Connected Equipment Against Damaging Surges And Line Noise. Four Outlets Are Grouped Into Two Load Banks That Let You Shed Non-Critical Loads To Extend Runtime For Critical Loads.Premium Protection From Emi/Rfi Line Noise Helps Your Equipment Perform Betterthis Ups System Filters Out Disruptive Electromagnetic And Radio Frequency Interference That Can Inflict Hardware Damage Or Data Loss. This Emi/Rfi Filtering Also Helps Your Connected Components Perform Better And Last Longer.Clear Lcd Interface Keeps You Informed At A Glancethe Menu-Driven Front-Panel Lcd Provides Detailed Alarms And Notifications To Help Diagnose Any Issues. It Provides System Status, Event Logs, Battery And Power Module Status, Usage Analytics, Serial Number, Firmware Update Info And More. Audible Alarms Can Be Disabled Through The Front Menu When The Ups Goes To Battery Power. The Lcd Rotates To Accommodate Both Rack-Mount And Tower Installation.Advanced Communications Ports Allow For Automatic Saves And Shutdownsrs-232 And Usb Ports Connect To A Device For A Variety Of Communication Options (Cables Are Included). A Dry-Contact Relay Port Can Be Programmed Through The Lcd To Provide Reliable Communications To Automation And Industrial Components. The Rpo/Roo Port Permits Emergency Shutdown Or Remote Restart Of All Connected Equipment.Automatically Turns Back On After Power Is Restoredbattery-Independent Restart Ensures Automatic Ups Power-Up Without User Interaction After Lengthy Power Outages, Even After A Complete Battery Discharge.Versatile Installation Optionsyou Can Mount The Su1500Rtxlcdn In Just 2U Of Space In An Eia-Standard 19-Inch Rack Using The Included Hardware. You Can Also Adapt It For Tower Installation Using The Included Support Stands Or Add The Optional Rk2Pc (Sold Separately) For 2-Post Rack Mounting. The Eight-Foot Power Cord With Nema 5-15P Plug Connects To A Compatible Ac Outlet.Package Includes: 1500Va 1350W 120V Double-Conversion Ups Webcardlxe Network Management Card Usb Cable
⚠️ WARNING (California Proposition 65): This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, please visit www.P65Warnings.ca.gov.
Frequently Asked Questions
Q: What are the dimensions of the Tripp Lite UPS?A: The Tripp Lite UPS measures nineteen point two inches long, twenty three point three inches wide, and nine point two inches high.
Q: What is the power capacity of the Tripp Lite UPS?A: The power capacity is one thousand five hundred volt-amperes and one thousand three hundred fifty watts.
Q: What type of output does the UPS provide?A: The UPS provides pure sine wave output, ensuring stable and reliable power for sensitive equipment.
Q: How do I install the Tripp Lite UPS?A: You can install the UPS in a standard EIA nineteen inch rack using the included mounting hardware or adapt it for tower installation.
Q: Can I add more battery modules to this UPS?A: Yes, you can connect up to four optional extended battery modules to increase runtime during outages.
Q: How do I connect my devices to the UPS?A: You can connect devices using the eight five-15R outlets available on the UPS.
Q: How do I maintain the Tripp Lite UPS?A: To maintain the UPS, ensure the batteries are replaced when needed and periodically check the LCD for system status updates.
Q: Is the UPS safe to use with sensitive equipment?A: Yes, the UPS is designed to protect sensitive equipment from power surges and line noise, making it safe to use.
Q: How should I store the Tripp Lite UPS?A: Store the UPS in a dry, cool location away from direct sunlight and ensure it is unplugged when not in use.
Q: What warranty does the Tripp Lite UPS come with?A: The UPS is covered by a two-year manufacturer's warranty, providing peace of mind for users.
Q: What kind of insurance is included with the UPS?A: The UPS comes with two hundred fifty thousand dollars in connected equipment insurance, offering additional protection.
Q: What should I do if the UPS arrives damaged?A: If the UPS arrives damaged, contact customer support immediately to initiate a return or exchange.
Q: How do I troubleshoot my UPS if it's not working?A: If the UPS is not working, check the connections and ensure it is properly plugged into a compatible AC outlet.
Q: Does the UPS have a remote management feature?A: Yes, the UPS includes a built-in network management card that allows for remote configuration and management.