3-Phase Pdu Distributes, Monitors And Manages Network-Grade Powerrecommended For Data Centers, Server Rooms And High-Density Network Closets, This Switched Pdu Provides Advanced Network Control And Remote Power Monitoring With The Ability To Turn On, Turn Off, Reboot Or Lock Out Power To Each Outlet. You Can More Efficiently Manage Network Power Consumption And Remotely Reboot Locked Network Items Without Having To Visit The Site. Reducing The Number Of On-Site Visits Can Help Lower The Cost Of Data Center Maintenance, Thus Lowering The 0U Pdus Total Cost Of Ownership.30 Outlets Dispense Ac Power To Connected Equipmentduring Normal Operation, 30 Individually Controllable Outlets-24 C13 And Six C19-In Three Load Banks Distribute Ac Power To Rack Equipment. Each 208/240V Outlet Is Accompanied By An Led That Illuminates When The Outlet Is Ramped Up And Ready To Be Used. The Outlets And Banks Can Be Individually Monitored To Ensure Proper Load Levels And Load Balancing. Plug-Lock Insert Sleeves Are Included To Prevent Connected Cables From Becoming Accidentally Dislodged.Built-In Lx Platform Network Management Card Allows Remote Access 24/7The Java-Free Html5-Based Lx Platform Network Interface Enables Full Remote Access For Pdu Status Monitoring And Email Notifications Via Secure Web Browser, Snmp, Telnet Or Ssh. It Supports 10/100/1000 Mbps Auto-Sensing For Optimum Communication With An Ethernet Network. Optional Envirosense2 Modules (Sold Separately) Provide A Variety Of Environmental Monitoring Capabilities. Protocols Supported Include Ipv4, Ipv6, Http, Https, Smtp, Snmpv1, Snmpv2, Snmpv3, Telnet, Ssh, Ftp, Dhcp And Ntp. The 0U Pdu Can Receive Ip Address Assignments Via Dhcp Server (Automatic) Or Static (Manual) Method.Color Touchscreen Lcd Offers Important Data At A Glancean Easy-To-Navigate Color Touchscreen Lcd Reports Network Data, Input Current Level Per Phase, And Output Current Per Load Bank And Per Outlet With 1% Billing-Grade Accuracy. It
⚠️ WARNING (California Proposition 65): This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, please visit www.P65Warnings.ca.gov.
Frequently Asked Questions
Q: What is the size of the PDU?A: The PDU measures seventy-five point eight inches in length, nine point six one inches in width, and six point two inches in height. This compact design allows for efficient use in various settings.
Q: What voltage does this PDU operate on?A: This PDU operates at two hundred eight to two hundred forty volts. It's suitable for three-phase power applications, ensuring reliable performance.
Q: How many outlets does this PDU have?A: This PDU features twenty-four C thirteen outlets and six C nineteen outlets. This variety accommodates multiple devices simultaneously.
Q: How do I install the PDU?A: To install the PDU, mount it in a standard rack and connect it to a power source. Ensure the power specifications match your setup for optimal performance.
Q: Is this PDU suitable for small businesses?A: Yes, this PDU is ideal for small businesses requiring robust power distribution. Its multiple outlets and monitoring capabilities enhance efficiency.
Q: Can I use this PDU in data centers?A: Yes, this PDU is designed for data centers, providing reliable power management for servers and networking equipment. Its switched capability allows for remote control.
Q: How do I maintain the PDU?A: To maintain the PDU, regularly check connections and clean dust from outlets. Ensure that it remains in a cool, dry place to extend its lifespan.
Q: Is this PDU safe for use?A: Yes, this PDU complies with TAA regulations, ensuring safety and reliability for your electrical devices. Always follow installation guidelines for maximum safety.
Q: What is the warranty on this PDU?A: The PDU typically comes with a manufacturer's warranty. Check with the retailer for specific terms and conditions regarding coverage.
Q: What should I do if the PDU does not work?A: If the PDU does not work, first check the power source and connections. If issues persist, contact customer support for further assistance.
Q: Can this PDU handle high-performance servers?A: Yes, this PDU can handle high-performance servers due to its robust design and power capacity. It's ideal for demanding applications.
Q: How do I troubleshoot outlet issues on the PDU?A: To troubleshoot outlet issues, test each outlet with a device to identify the malfunctioning ones. Ensure all connections are secure and check the power source.
Q: Does this PDU provide power monitoring?A: Yes, this PDU includes monitoring features that allow you to track power usage. This data helps optimize energy consumption in your setup.
Q: Is this PDU compatible with UPS systems?A: Yes, this PDU is compatible with UPS systems for backup power solutions. It ensures continued operation during power interruptions.
Q: What materials is this PDU made from?A: The PDU is constructed from durable materials designed to withstand electrical loads. Its robust design ensures longevity and reliability.